Weatherproofing Cold Shrink Tube for 12-40mm Connection
Cold shrink tube is designed for weatherproofing protection on connections between jumper cable and connector (7-16 DIN, N type or 4.3-10) of wireless equipment, such as RRU, Antenna and Microwave. Comparing with tape sealing protection, cold shrink tube installation is much shorter (15-30 seconds), convenient installation, uniform appearance for acceptance.
Features
» High elastic silicone rubber tube structure with mastic built-in for better weatherproofing protection;
» Stable and long life during operation;
» Fast installation, only 15-30 seconds needed to seal one connection;
» Perfect SWR performance approved by telecom operators;
» Good operating capability under extreme cold and hot condition, anti-UV, anti-ozone;
» Much time and labor cost saving;
Properties
Item | Parameter and Result | Test Method | |
Waterproof | Class | Pass, IPX7 | IEC 60529:1989/AMD2:2013/COR1:2019 1 meter depth in water, duration: 30 minutes |
Physical and mechanical properties | Shore Hardness | A/41/1 | ASTM D2240-15 |
Tensile Strength | 9.66 MPa | ASTM D412-16 Method A | |
Elongation | 930% | ASTM D412-16 Method A | |
Tear Strength | 28.4 N/mm | ASTM D624-00 | |
Brittleness Temperature by Impact | Pass | ASTM D746-14,-60℃ | |
Drop Test | Pass No damage, deformation, and support tube could be pulled out normally | Drop from height 1.2m on tile floor surface, 3 times to test | |
Flammability | Horizontal Burning | HB | UL 94-2013 Rev.14-2022 Section 7 |
Electricity | Dielectric Strength | 19.10 KV/mm | ASTM D149-20 Method A |
Performance under harsh environment | Mechanical and Waterproof Properties | No crack, discoloration, damage or deformation, IPX7 Pass
| 1. Dry heat test (IEC 60068-2-2:2008 Test Bb): 90±2℃,168 hours; 2. Low temperature test (IEC 60068-2-1:2008Test Ab): -40±2℃,168 hours; 3. Thermal cycling test: Cycle time:12h/cycle, Cycle index: 10 cycles, Total duration: 120 hours; 4. Damp heat test, cyclic test (IEC 60068-2-30:2005 Test Db):Cycle time:24h/cycle, Cycle index: 10 cycles, Total duration: 240 hours; 5. Damp heat test, steady state (IEC 60068-2-78:2012 Test Cab):Temperature: 75±2℃, Humidity:(95±1) %RH, Total duration: 1000 hours |
Aging Test | Light Aging Test-UV Exposure | No crack, discoloration, damage or deformation Grey scale: 4-5 IPX7 Pass | ISO 4892-3:2016Cycle1& ISO 105-A02:1993/Cor.2:2005 Lamp type: UVA-340, 8h UV at (60±3)℃ BPT,0.76W/(m²×nm)@340nm 4h condensation at(50±3)℃ BPT Exposure duration:1000 hours |
Ozone Aging | No crack, discoloration, damage or deformation, IPX7 Pass | ASTM D1149-16 Method B procedure B1 Temperature: 40±1℃ Ozone concentration:50±5 pphm Exposure duration: 72 hours | |
Hailstone Resistant Test | No crack,damage or deformation | IEC 61215,φ20mm hailstone falling | |
Material | Environmental Protection | RoHS Reach | IEC 62321 SVHC |
Temperature | Installation Temperature | -40℃ ∼ 60℃ | Refer to “mechanical properties” and “performance under harsh environment” |
Operation Temperature | -60℃ ∼ 80℃ | ||
Stock Temperature | -60℃ ∼ 80℃ |
Applications
» Provides excellent physical protection and moisture sealing for telecom connectors and cables.
» Perfect application for remote radio unit connections.
» Cable jacket and sheath repairs.
» Corrosion protection for fittings and couplings.
Specification
Product Name: Cold Shrink Tube
Product Code: CST45-125-12
Material: Silicone rubber
Inner Diameter of Plastic Core: 45mm
Diameter (after shrink): 12mm
Length (after shrink): 125mm
Application: Sealing 12-40mm connection
MOQ: 1000
Sample Offered: Free at our cost
Shipment Method: Sea way, air way, DHL, UPS, FedEx, etc.
Port of Shipment: Shanghai, China